Home / Products / Biosafety Cabinets

Biological Ventilation

Biosafety Cabinets

Certified by an NSF 49-listed technician

Simultaneous protection of the operator, product, and environment against hazardous biological agents. Equipment with HEPA filtration and directional airflow for safe work with pathogens of different risk levels.

Quick facts
Available types
Class I. Class II types: A2, B2. Class III
Inflow Velocity
100 fpm
Window operation
Fixed / Hinged
Filtration
HEPA - ULPA
Complies with and is tested under
NSF 49
EN 12469
ISO 14644
Equipment anatomy

Designed component by component

Each subsystem meets a regulatory requirement and a real operator need. This is what goes into the equipment.

MID MONITOR

Digital monitor with hot-wire sensor

GREATER VISIBILITY

Glass front and sides for maximum visibility

DOUBLE FILTRATION

Long-lasting HEPA filters.

REMOVABLE TRAY

304 Stainless Steel spill tray

Certified

The only one with FAT and SAT certification by an NSF-certified and listed technician.

Regulatory traceability

We don't just say it complies. We prove it.

Every standard requires a verifiable parameter. This is the exact correspondence between the requirement and how C4 equipment guarantees it — with documented factory and on-site testing.
Standard
Requirements
How C4 complies
NSF 49.

A2/B2 Inflow 100 fpm

Front micro-perforated grilles calculated to ensure inflow frontal stability.

NSF 49

downflow ± 2 fpm

design

HEPA filters with a flow-stabilizing grid that ensures design velocities.

ISO 14644

Maximum particles

≥ 0.5 μm: max. 3,520 particles ≥ 1.0 μm: max. 832 particles ≥ 5.0 μm: max. 29 particles

Engineering

Features that make the difference

Premium materials, active control, and construction designed for decades of operation in critical environments.
The C4 Advantage

Regional manufacturing, not importation

40 years of manufacturing in LATAM allow us to adapt each piece of equipment to local regulations and provide support that an importer cannot match.

With C4

Minimum 10-year guarantee on spare parts availability

Warranty plans exceeding 3 years

Performance guarantee under the specific conditions of each LATAM laboratory according to NSF 49

Guarantee of HEPA filters without replacement for at least 2 years

Imported equipment

No way to ensure spare parts locally for more than 2 years

Warranties limited to 1 year.

Performance guarantee of an old NSF-certified model

Filters requiring replacement every 6 months and difficult to source

Applications

Where this equipment works

Sectors where operator and process protection leave no room for improvisation.

MICROBIOLOGICAL CULTURE

DNA EXTRACTION

DIAGNOSTIC LAB

DRUG COMPOUNDING

How we work

From consultation to certified equipment

A guided engineering process, not a catalog sale. This is how we manage every project.
01

Diagnosis

We evaluate your application, local regulations, and space constraints.
02

Custom design

Technical specifications and blueprints adapted to your process.
03

Manufacturing

In-house production with documented quality control.
04

Validation

Installation and certification at the factory and on-site.

Complementary solutions

You may also be interested in

Fume Hoods

working with chemical reagents

Personal protection against chemical risk

Laminar flow cabinets

working with non-pathological processes

Process protection from the external environment.

passbox

safe material transfer

Protection of production areas.

Let's talk about your project, not a catalog

Our engineers provide a technical specification adapted to your application and local regulations — with no obligation.
Scroll to Top